Last update: 4 January 2013

Both DID and outgoing calls work. However, in order for the outgoing calls to work one must set From: "XXXXXXXXXX". That does not seem to be achievable with the gateway params/vars (at least I could not find the way), so dialplans need to set some vars.


For v.1.2.x:

  ...
    <action application="export" data="effective_caller_id_name=XXXXXXXXXX" />
    <action application="export" data="effective_caller_id_number=XXXXXXXXXX" />
    <action application="bridge" data="sofia/gateway/Internode/$1" />
    ...

For v.1.0.6:;

 ...
    <action application="export" data="sip_cid_type=none" />
    <action application="bridge" data="sofia/gateway/Internode/$1" />
    ...

 

It is possible that only one is enough.